In previous parts of this series, we have covered the basics, inputs, outputs, and jumper configuration of the C8 board.  If you missed any of these parts, you can find them here:

Part 1 - Power and LEDs
Part 2 - Inputs
Part 3 - Outputs
Part 4 - Jumpers

In this, the final part of the series, we will explain the usage of our Excel Jumper Configuration Tool.

About the Tool

The C4/C8 Jumper Configuration Tool is available free for download from the LifeSafety Power website's Calculators page, or by clicking here.

The tool uses information entered by the user to determine the correct jumper settings.  Even if you have the jumper settings memorized, the tool is very helpful in quickly configuring multiple zones.  Jumper settings can be predetermined in the office, printed, and included in the system design documentation, or done on-the-fly at the job site.

Using the Tool

To begin, open the file in Excel.  There are three sections on the screen - Voltage Sources, Zone Information, and Results.

Main Screen

Step 1 - Voltage Sources
The Voltage Sources section is where you enter the B1 and B2 voltages used as the power source for the C8.  In a single voltage system, only the B1 field will have information entered.  The B2 field should be left blank.

A dual voltage system should have both the B1 and B2 fields filled in as appropriate.  Remember that a dual FPO system (as built by LifeSafety Power) would have the top FPO's voltage in the B1 space and the bottom FPO's voltage in the B2 space.  An FPO/B100 system would have the FPO's voltage as B1 and the B100's voltage as B2.

Entering this information correctly is important for the yellow jumper's setting.  Reversing this data will cause the incorrect output voltage to be placed on the outputs, potentially damaging the powered equipment.  Remember to always double check your output voltages before connecting any load devices.

The B1/B2 information will remain consistent across all boards and zones in a typical FPO power supply system.

Step 1

In this example, the B1 supply is set for 24V and the B2 supply is set for 12V.

Step 2 - Zone Information
The Zone Information section is where you enter the information for the zone being configured.  This information may vary zone to zone.

  • Input Type - This drop-down selection allows you to choose the type of input connected to the input terminals for the zone.  Selections include NO or NC contact, remove or apply voltage, open collector, or no input.  The NO or NC contact selections are the most typical input types and would be used for a relay contact, pushbutton, etc.  The remove or apply voltage settings would activate the zone when a voltage is either removed from or applied to the B terminal of the input.  Open collector would be the setting to use for a transistor output, and "no input" would be the selection to use if you wanted a constant voltage output without input control.
  • Output Type - This drop-down selection allows you to choose the output type for the zone.  Selections include mag lock, fail safe or fail secure strike, NO or NC relay contact output, or constant output.  Choose the closest match for the output type needed (i.e. for an electrified handleset choose fail secure strike, since the operation is very similar).
  • Output Voltage - This drop-down will be populated with the values entered in the B1 and B2 fields in the Voltage Sources section above.  Select which voltage is desired for the zone.
  • Zone FAI? - This drop down has two selections - yes or no - to select whether the zone should react when an FAI is received on the FPO power supply.

Step 2

In this example, the input is set for a NO Dry Contact and the output is set for a 24V maglock with FAI.

Step 3 - Results
The results section displays the correct jumper settings for the configuration entered in steps 1 and 2.  Jumpers A-F are shown with a visual representation of positions 1 and 2 for each jumper.  Remember to look closely at the C8 PC Board for positions 1 and 2 for each jumper carefully, as these positions change from jumper to jumper.

Step 3

Conclusion

I hope this series has been useful to you and has helped you to become an expert in using the C8 family of lock control boards.  If you need any assistance, our This e-mail address is being protected from spambots. You need JavaScript enabled to view it department is here to help.

Published in Blog
Friday, 18 September 2015 11:33

Understanding the C8 Board - Part 3 - Outputs

In the previous two parts of this series, we covered the very basics and the inputs of the C8 board.  If you missed these parts, you can find them here:

Part 1 - Power and LEDs
Part 2 - Inputs

This week we will go in-depth on the outputs of the C8, including the wiring, operation, and jumper configuration.

The Anatomy of the C8 Output

Like the inputs, each output of the C8 has two terminals, labeled A and B.  Each output may be individually configured for a voltage output or a relay output and contains a reverse diode to dissipate and reverse EMF from a locking device or other inductive load.  See our White Paper and Application note on reverse EMF for more information.

When configured as a voltage output, the B terminal is the positive and the A terminal is the DC Common (ground).

C4

C8 Voltage Output

When configured as a relay output, due to the reverse diode, the current must be fed through the contact in the proper direction.  Regardless of what the relay output is activating, there will be a current present.  If the relay output of the C8 is connected backwards, the reverse diode will always be conducting and will not change with the relay.

C1

C8 Relay Output

Each output has four configuration jumpers, detailed below.

Black Jumpers (C and E)

The black jumpers for each zone, labeled C and E, configure the output for either a voltage output or a relay output.  BOTH jumpers must always be set in the same position (by the jumpers' markings) for proper operation.  Check the position markings carefully on the PC board, as position 1 and 2 for each of the black jumpers is different.

By setting the black jumpers in position 1, the output will be configured for a relay output.  By setting these jumpers to position 2, the output will be configured as a voltage output.

White Jumper (F)

The white jumper selects between the NO and NC of the output relay.  When set for a relay output, this selects a NO or NC output.  When set for a voltage output, this selects whether the output is normally powered or not powered (maglock or doorstrike). 

By setting the white jumper in position 1, the output will be NO or will normally have no voltage on the output until the input is activated (flashing green LED).  This is the typical setting for a fail-secure door strike or electrified handleset.

By setting the white jumper in position 2, the output will be NC or will normally have voltage present on the output until the input is activated.  This is the typical setting for a fail-safe maglock.

Again, there is no need to memorize all of the settings - once the blue jumper for the input is set properly (steady when locked, flashing when unlocked - see Part 2), the white jumper can be changed until the output operates correctly.

Yellow Jumper (D)

The yellow jumper selects between the buss 1 and buss 2 voltage supplied to the C8 for each output (See Part 1).  If only a single voltage source is connected to the C8, then this jumper should remain in position 1.  If two power sources are connected to the C8, then setting this jumper in position 1 will select the voltage source connected to B1 and position 2 will select the B2 power source.

Note that this jumper has no effect when the output is set as a relay output.

Voltage Output

The most common output configuration for a C8 is a voltage output.  When connecting a device to the terminals when set as a voltage output, the positive connection goes to the B terminal and the negative connection goes to the A terminal.

C2

C8 Voltage Output Wiring

Relay Output

When configured as a relay output, the current through the relay must flow from the B terminal to the A terminal (the more positive side of the voltage on the B terminal).  Note that ONLY a DC voltage may be switched through the C8 relay due to the reverse polarity diode.

C3

C8 Relay Output Wiring

Next Week

Next week we will go into detail on the jumper settings of the C8, including the usage of our Excel-based C8 Jumper Configuration Tool.  Until then, if you need any assistance, our This e-mail address is being protected from spambots. You need JavaScript enabled to view it department is here to help.

Published in Blog