The M8 Managed Lock Power Module communicates with a LifeSafety Power NetLink® module and provides eight monitored and controlled voltage outputs accessible from a network or the internet. Optional RS485 connection for remote monitoring through NetLink using RSMOD (not included). The M8 provides eight control inputs capable of voltage or dry contact activation and eight controlled and monitored outputs, with each output network programmable for fail-safe, fail-secure, fi re alarm over ride, and AC loss over ride for egress lock control.
The FlexPower C4, C8 lock controller modules add either 4 or 8 lock control outputs to a FlexPower power supply and are typically supplied as part of a system or purchased as an expansion piece to an existing system. Each module provides either 4 or 8 access control inputs capable of voltage or dry contact activation. Each module provides either 4 or 8 lock outputs, each one programmable for fail-safe, fail-secure, dry contact, and fi re alarm over ride for egress lock control.
The FlexPower F8 module is a Fire Alarm Interrupt (FAI) controlled distribution accessory that provides eight zones of fused or PTC-protected power distribution with FAI control. The F8 accepts one or two DC power inputs, either of which are available on any output zone. Each output is also selectable for continuous output, enable on FAI, or disable on FAI. The suffix "P" added to the model number denotes Class 2 Power limited outputs.
Need help selecting a product? Try our Product Selector and drag and drop Configurator!
Model | Order As | Standard / Managed | Output Type | Inputs | Outputs | Current per Zone | Zone Inputs | Fuse Type | Data Sheets | Manuals | CAD Files |
---|---|---|---|---|---|---|---|---|---|---|---|
M8 | M8-Boxed | Managed, Network Ready | Lock Power Distribution | 8 | 8 | 3A | Yes | Fused, Automotive style |
M8/M8P | n/a | |
M8P | M8P-Boxed | Managed, Network Ready | Lock Power Distribution |
8 | 8 | 2.5A | Yes | Class 2 Power Limited | M8/M8P | n/a | |
C4 | C4-Boxed | Standard | Lock Power Distribution | 4 | 4 | 3A | Yes | Fused, Automotive style | C4/C8 | C4/C4P CAD | |
C4P | C4P-Boxed | Standard | Lock Power Distribution | 4 | 4 | 2.5A | Yes | Class 2 Power Limited |
C4/C8 | C4/C4P CAD | |
C8 | C8-Boxed | Standard | Lock Power Distribution | 8 | 8 | 3A | Yes | Fused, Automotive style | C4/C8 | C8/C8P CAD | |
C8P | C8P-Boxed | Standard | Lock Power Distribution | 8 | 8 | 2.5A | Yes | Class 2 Power Limited |
C4/C8 | C8/C8P CAD | |
F8 | F8-Boxed | Standard | FAI Egress | FAI | 8 | 3A | No | Fused, Automotive style | F8/F8P | F8/F8P CAD | |
F8P | F8P-Boxed | Standard | FAI Egress | FAI | 8 | 2.5A | No | Class 2 Power Limited |
F8/F8P | F8/F8P CAD |