LenelS2 IntegrationNetLink integration with LenelS2 OnGuard provides full power system monitoring and control capabilities to OnGuard. Power system alerts, parameter measurements, and system control features are all available directly from the OnGuard interface, streamlining system maintenance and maximizing system uptime. Integration to OnGuard is through integration software via OAAP. LenelS2 OAAP Integration  DownloadDescription | Latest Revision | Software File | User Manual | Release Notes | LenelS2 OnGuard Integration | 1.12 | Download | IM | RN | Requirements & InformationItem | Information | OnGuard Version Supported | 7.6, 8.0 | OnGuard License Required | Yes - See Below | NetLink Boards Supported | NL2, NL4, NLX | NetLink Minimum Firmware Version | 9.18 or above | Integration Type | SNMP Trap | Integration Level | Alerts | License Numbers (Purchased through LenelS2)SKU | Description | IPC-321-LSP01-B | If System Purchased Through LenelS2 Direct - Initial License - 10 Panels / power devices | IPC-321-010 | If System Purchased Through LenelS2 Direct - License and support of 10 additional panels / power devices | IPC-344-LSPZ01-B | If System Not Purchased Through LenelS2 Direct - Initial License - 10 Panels / power devices | IPC-344-010 | If System Not Purchased Through LenelS2 Direct - License and support of 10 additional panels / power devices | Contact LenelS2 for more licensing information. | Supported AlertsAlert | Supported | AC Fault Alert | ● | System Fault Alert | ● | Fire Alarm Active | ● | Power Supply Service Due | ● | Insufficient Battery Standby Time | ● | Battery Replacement Due | ● | M8 Output Voltage Out of Range | ● | M8 Output Current Out of Range | ● | Enclosure Temperature Out of Range | ● | External Temperature (IDF Closet) Out of Range | ● | Tamper Switch Alert | ● | Device Detect (Connected or disconnected from NetLink) | ● | Current Sensor Out of Range | ● | Auxiliary Voltage Out of Range | ● | Values ReportedValue | Supported | AC Input Voltage | | Power Supply Output Voltage | | Power Supply Total Output Current | | Battery Voltage | | Battery Charge / Discharge Current | | M8 Output (Lock) Voltage | | M8 Output (Lock) Current | | M8 Output (Lock) Cycle Count | | Enclosure Temperature | | External Temperature (IDF Closet) | | Current Sensor Measurement | | Auxiliary Voltage Measurement | | Control FeaturesControl Item | Supported | Start / Schedule Automated Battery Test | | Power Cycle M8 Output | | Power Cycle Power Supply Main Output | | NetLink Control 1 / Control 2 Outputs | | |