PDF Print E-mail

PCLASS

Integrated Paxton Access Power

All-in-one multi-door power solutions for Paxton Net2 and BLU controllers. Single and Dual Voltage, Standard and Networked.
PCLASS Product Guide

HClass
  • Products

  • Overview

  • Technical Documents

  • Support

  • Tools & Software


Standard Power
Doors Single Voltage Current/Voltage Enclosure Outputs *Access Mounting
4 FPO75-D8E4P 6A/12V 24Hx20Wx6.5D 8 auxiliary Up to six (6) controllers
8 FPO150-2D8E6P 12A/12V 30Hx23Wx6.5D 16 auxiliary Up to nine (9) controllers
16 FPO250-4D8E8P 20A/12V 36Hx30Wx6.5D 32 auxiliary Up to fourteen (14) controllers
Doors Dual Voltage
4 FPO75-B100D8E4P 2A/12V and 2A/24V 24Hx20Wx6.5D 8 auxiliary Up to six (6) controllers
8 FPO150-B1002D8E6P 4A/12V and 4A/24V 30Hx23Wx6.5D 16 Aauxiliary Up to nine (9) controllers
16 FPO150/250-4D8E8P 12A/12V and 10A/24V 36Hx30Wx6.5D 32 auxiliary Up to twelve (12) controllers
Managed Power
Doors Single Voltage
4 FPO75-M8NL4E4P 6A/12V 24Hx20Wx6.5D 8 auxiliary Up to six (6) controllers
8 FPO150-D8M8NL4E6P 12A/12V 30Hx23Wx6.5D 16 auxiliary Up to nine (9) controllers
16 FPO250-2D82M8NL4E8P 20A/12V 36Hx30Wx6.5D 32 auxiliary Up to twelve (12) controllers
Doors Dual Voltage
4 FPO75-B100M8NL4E4P 2A/12V and 2A/24V 24Hx20Wx6.5D 8 managed Up to six (6) controllers
8 FPO150-B100D8M8NL4E6P 4A/12V and 4A/24V 30Hx23Wx6.5D 8 auxiliary
8 managed
Up to nine (9) controllers
16 FPO150/250-2D82M8NL4E8P 12A/12V and 10A/24V 36Hx30Wx6.5D 16 auxiliary
16 managed
Up to twelve (12) controllers
Enclosures
*Doors
Part Number Size
4 E2P 20Hx16Wx 4.5D
6 E4P 24Hx20Wx6.5D
9 E6P 30Hx23Wx6.5D
14 E8P 36Hx30Wx6.5D
*Count can increase with controller double stacking

Integrated Access & Power

  • PCLASS all-in-one systems puts power and Paxton NET2 or BLU controllers in one secure locking enclosure
  • One AC drop minimizes wall space, simplifies installation, reduces time & labor costs
  • FlexPowerTM modularity and PCLASS versatility create unlimited system configurations
  • Network options for diagnostic monitoring and control of power, battery and connected devices

Labor Saving Enclosure Design

  • Factory pre-wired power section saves configuration time
  • Removable backplate simplifies controller wiring
  • Large enclosure depth accomodates battery sets
  • Multiple knockout areas along all four sides

System Refinements

  • Fault detection and reporting to host power and over the network with optional NetLink module
  • Large enclosures with room for increased power, added output distribution or remote monitoring
  • Modular power and distribution boards with snap-in standoffs simplify service and field upgrades
  • Cam lock set, tamper switch and backplate hardware to mount the access control panels is included

PRODUCT HIGHLITES

PCLASS unified power systems offers maximum flexibility, functionality and savings to access system designers.

PCLASS enclosures are engineered to house FlexPowerTM power management boards alongside Paxton AccessTM NET2 controllers in one compact, secure system.

To prevent damage to system electronics, the backplate seperates from the enclosure for NET2 mounting in the shop while wiring is pulled to the enclosure at the job site. Once configured, the backplate can be remounted for final ties and checkout.

Features

  • Removable back plate simplifies job installation
  • Engineered backplate pattern minimizes installation time
  • Power boards mount on snap-in stand offs
  • Access boards mount on supplied threaded metal standoffs

Mechanical Refinements

  • Large enclosure depth to accommodate battery
  • 19 Gauge steel with textured black finish
  • Board mounting hardware provided
  • Lock and tamper switch standard

Reliability and Safety

  • Lifetime Warranty
  • RoHS Compliant

Agency Listings

  • UL 294 / UL 603
  • UL 1076
  • ULC S318, 319,
  • FCC Part 15, Subpart B
  • CSA C22.2 107.1
  • CSA 22.2 #60950

agency box

Product Warranty


Standard Paxton Power
Single Voltage Datasheet Install Manuals CAD Files Agency
FPO75-D8E4P DS IM CAD AG
FPO250-2D8E6P DS IM CAD AG
FPO250-4D8E8P DS IM CAD AG
Dual Voltage
FPO75-B100D8E4P DS IM CAD AG
FPO150-B1002D8E6P DS IM CAD AG
FPO150/250-4D8E8P DS IM CAD AG
Managed Paxton Power
Single Voltage
FPO75-D8NL2E4P DS IM CAD AG
FPO150-D8M8NL4E6P DS IM CAD AG
FPO250-2D82M8NL4E8P DS IM CAD AG
Dual Voltage
FPO75-B100M8NL4E4P DS IM CAD AG
FPO150-B100D8M8NL4E6P DS IM CAD AG
FPO150/250-2D82M8NL4E8P DS IM CAD AG
Enclosures
E2P DS CAD
E4P DS CAD
E6P DS CAD
E8P DS CAD

Troubleshooting Guide Factory Contact Business Contact
FPO Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Accessory Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it Area Sales Representatives

Tools & Software