Feenics IntegrationNetLink integration with Feenics provides alerts and control capabilities to Keep. Power system alerts and system control features are available directly from the Keep interface, streamlining system maintenance and maximizing system uptime. Integration to Keep is via the native Mercury Integration and is supported by Feenics.  Requirements & InformationItem | Information | Keep Version Supported | | Feenics License Required | None | NetLink Boards Supported | NL2, NL4 | NetLink Minimum Firmware Version | 9.18 or above | Integration Type | PSIA / XML | Integration Level | Alerts & Control | Supported AlertsAlert | Supported | AC Fault Alert | ● | System Fault Alert | ● | Fire Alarm Active | ● | Power Supply Service Due | ● | Insufficient Battery Standby Time | ● | Battery Replacement Due | ● | M8 Output Voltage Out of Range | ● | M8 Output Current Out of Range | ● | Enclosure Temperature Out of Range | ● | External Temperature (IDF Closet) Out of Range | ● | Tamper Switch Alert | ● | Device Detect (Connected or disconnected from NetLink) | ● | Current Sensor Out of Range | ● | Auxiliary Voltage Out of Range | ● | Values ReportedValue | Supported | AC Input Voltage | | Power Supply Output Voltage | | Power Supply Total Output Current | | Battery Voltage | | Battery Charge / Discharge Current | | M8 Output (Lock) Voltage | | M8 Output (Lock) Current | | M8 Output (Lock) Cycle Count | | Enclosure Temperature | | External Temperature (IDF Closet) | | Current Sensor Measurement | | Auxiliary Voltage Measurement | | Control FeaturesControl Item | Supported | Start / Schedule Automated Battery Test | ● | Power Cycle M8 Output | ● | Power Cycle Power Supply Main Output | ● | NetLink Control 1 / Control 2 Outputs | ● | | |
Software House IntegrationNetLink integration with Software House C●CURE9000 provides full power system monitoring and control capabilities to C●CURE. Power system alerts, parameter measurements, and system control features are all available directly from the C●CURE interface, streamlining system maintenance and maximizing system uptime. Integration to C●CURE is via a driver download. Before installing, a license must be obtained from Software House. Compatibility Matrix  DownloadDescription | Latest Revision | Software File | User Manual | Release Notes | C●CURE 2.9 Integration | 8.9.6.29 | Download | IM | RN | C●CURE 2.8 Integration | 8.9.6.28 | Download | IM | RN | C●CURE 2.7 Integration | 8.8.9.27 | Download | IM | RN | Requirements & InformationItem | Information | C●CURE Version Supported | 2.7, 2.8, 2.9 | Software House License Required | Yes | NetLink Boards Supported | NL2, NL4, NLX | NetLink Minimum Firmware Version | 9.18 or above | Integration Type | Native | Integration Level | Full Integration | Supported AlertsAlert | Supported | AC Fault Alert | ● | System Fault Alert | ● | Fire Alarm Active | ● | Power Supply Service Due | ● | Insufficient Battery Standby Time | ● | Battery Replacement Due | ● | M8 Output Voltage Out of Range | ● | M8 Output Current Out of Range | ● | Enclosure Temperature Out of Range | ● | External Temperature (IDF Closet) Out of Range | ● | Tamper Switch Alert | ● | Device Detect (Connected or disconnected from NetLink) | ● | Current Sensor Out of Range | ● | Auxiliary Voltage Out of Range | ● | Values ReportedValue | Supported | AC Input Voltage | ● | Power Supply Output Voltage | ● | Power Supply Total Output Current | ● | Battery Voltage | ● | Battery Charge / Discharge Current | ● | M8 Output (Lock) Voltage | ● | M8 Output (Lock) Current | ● | M8 Output (Lock) Cycle Count | ● | Enclosure Temperature | ● | External Temperature (IDF Closet) | ● | Current Sensor Measurement | ● | Auxiliary Voltage Measurement | ● | Control FeaturesControl Item | Supported | Start / Schedule Automated Battery Test | ● | Power Cycle M8 Output | ● | Power Cycle Power Supply Main Output | ● | NetLink Control 1 / Control 2 Outputs | ● | | Genetec IntegrationNetLink integration with Genetec's Security Center provides full power system monitoring and control capabilities to Security Center. Power system alerts, parameter measurements, and system control features are all available directly from the Security Center interface, streamlining system maintenance and maximizing system uptime. Integration to Security Center is via the LSPEntity software package. LSPEntity allows adding NetLink devices into Genetec's Security Center as an Entity. Before installing, a license must be obtained from Genetec under part number GSC-1SDK-LSP-NetLink. Genetec Security Center Integration  DownloadDescription | Latest Revision | Software File | User Manual | Release Notes | LSPEntity Genetec Integration | 2.15 | Download | IM | RN | Requirements & InformationItem | Information | Security Center Version Supported | 5.7, 5.8, 5.9, 5.10, 5.11 | Genetec License Required | GSC-1SDK-LSP-NetLink | NetLink Boards Supported | NL2, NL4, NLX | NetLink Minimum Firmware Version | 9.18 or above | Integration Type | SNMP Trap | Integration Level | Full Integration | Supported AlertsAlert | Supported | AC Fault Alert | ● | System Fault Alert | ● | Fire Alarm Active | ● | Power Supply Service Due | ● | Insufficient Battery Standby Time | ● | Battery Replacement Due | ● | M8 Output Voltage Out of Range | ● | M8 Output Current Out of Range | ● | Enclosure Temperature Out of Range | ● | External Temperature (IDF Closet) Out of Range | ● | Tamper Switch Alert | ● | Device Detect (Connected or disconnected from NetLink) | ● | Current Sensor Out of Range | ● | Auxiliary Voltage Out of Range | ● | Values ReportedValue | Supported | AC Input Voltage | ● | Power Supply Output Voltage | ● | Power Supply Total Output Current | ● | Battery Voltage | ● | Battery Charge / Discharge Current | ● | M8 Output (Lock) Voltage | ● | M8 Output (Lock) Current | ● | M8 Output (Lock) Cycle Count | ● | Enclosure Temperature | ● | External Temperature (IDF Closet) | ● | Current Sensor Measurement | ● | Auxiliary Voltage Measurement | ● | Control FeaturesControl Item | Supported | Start / Schedule Automated Battery Test | ● | Power Cycle M8 Output | ● | Power Cycle Power Supply Main Output | ● | NetLink Control 1 / Control 2 Outputs | ● | | | LenelS2 IntegrationNetLink integration with LenelS2 OnGuard provides full power system monitoring and control capabilities to OnGuard. Power system alerts, parameter measurements, and system control features are all available directly from the OnGuard interface, streamlining system maintenance and maximizing system uptime. Integration to OnGuard is through integration software via OAAP. LenelS2 OAAP Integration  DownloadDescription | Latest Revision | Software File | User Manual | Release Notes | LenelS2 OnGuard Integration | 1.12 | Download | IM | RN | Requirements & InformationItem | Information | OnGuard Version Supported | 7.6, 8.0 | OnGuard License Required | Yes - See Below | NetLink Boards Supported | NL2, NL4, NLX | NetLink Minimum Firmware Version | 9.18 or above | Integration Type | SNMP Trap | Integration Level | Alerts | License Numbers (Purchased through LenelS2)SKU | Description | IPC-321-LSP01-B | If System Purchased Through LenelS2 Direct - Initial License - 10 Panels / power devices | IPC-321-010 | If System Purchased Through LenelS2 Direct - License and support of 10 additional panels / power devices | IPC-344-LSPZ01-B | If System Not Purchased Through LenelS2 Direct - Initial License - 10 Panels / power devices | IPC-344-010 | If System Not Purchased Through LenelS2 Direct - License and support of 10 additional panels / power devices | Contact LenelS2 for more licensing information. | Supported AlertsAlert | Supported | AC Fault Alert | ● | System Fault Alert | ● | Fire Alarm Active | ● | Power Supply Service Due | ● | Insufficient Battery Standby Time | ● | Battery Replacement Due | ● | M8 Output Voltage Out of Range | ● | M8 Output Current Out of Range | ● | Enclosure Temperature Out of Range | ● | External Temperature (IDF Closet) Out of Range | ● | Tamper Switch Alert | ● | Device Detect (Connected or disconnected from NetLink) | ● | Current Sensor Out of Range | ● | Auxiliary Voltage Out of Range | ● | Values ReportedValue | Supported | AC Input Voltage | | Power Supply Output Voltage | | Power Supply Total Output Current | | Battery Voltage | | Battery Charge / Discharge Current | | M8 Output (Lock) Voltage | | M8 Output (Lock) Current | | M8 Output (Lock) Cycle Count | | Enclosure Temperature | | External Temperature (IDF Closet) | | Current Sensor Measurement | | Auxiliary Voltage Measurement | | Control FeaturesControl Item | Supported | Start / Schedule Automated Battery Test | | Power Cycle M8 Output | | Power Cycle Power Supply Main Output | | NetLink Control 1 / Control 2 Outputs | | | BluB0X IntegrationNetLink integration with BluB0X provides alerts, measurements, and control capabilities to BluSKY. Power system alerts, measurements, and system control features are available directly from the BluSKY interface, streamlining system maintenance and maximizing system uptime. Integration to BluSKY is via PSIA/XML and is supported by BluB0X.  Requirements & InformationItem | Information | BluSKY Version Supported | | BluB0X License Required | | NetLink Boards Supported | NL2, NL4 | NetLink Minimum Firmware Version | 9.18 or above | Integration Type | PSIA / XML | Integration Level | Full | Supported AlertsAlert | Supported | AC Fault Alert | ● | System Fault Alert | ● | Fire Alarm Active | ● | Power Supply Service Due | ● | Insufficient Battery Standby Time | ● | Battery Replacement Due | ● | M8 Output Voltage Out of Range | ● | M8 Output Current Out of Range | ● | Enclosure Temperature Out of Range | ● | External Temperature (IDF Closet) Out of Range | ● | Tamper Switch Alert | ● | Device Detect (Connected or disconnected from NetLink) | ● | Current Sensor Out of Range | ● | Auxiliary Voltage Out of Range | ● | Values ReportedValue | Supported | AC Input Voltage | | Power Supply Output Voltage | ● | Power Supply Total Output Current | | Battery Voltage | ● | Battery Charge / Discharge Current | ● | M8 Output (Lock) Voltage | ● | M8 Output (Lock) Current | ● | M8 Output (Lock) Cycle Count | | Enclosure Temperature | ● | External Temperature (IDF Closet) | ● | Current Sensor Measurement | ● | Auxiliary Voltage Measurement | ● | Control FeaturesControl Item | Supported | Start / Schedule Automated Battery Test | ● | Power Cycle M8 Output | ● | Power Cycle Power Supply Main Output | ● | NetLink Control 1 / Control 2 Outputs | ● | | |
|
|
|
|